• DocumentCode
    2513209
  • Title

    Conducted interference reduction from compact fluorescents lamps

  • Author

    Ferreira, P. I L ; Fontgalland, G. ; Aragao, G.F. ; Nascimento, A. R Z ; Freire, R.C.S. ; Barbin, S.E.

  • Author_Institution
    Dept. of Electr. Eng., Fed. Univ. of Campina Grande, Campina Grande, Brazil
  • fYear
    2010
  • fDate
    12-16 April 2010
  • Firstpage
    309
  • Lastpage
    312
  • Abstract
    This paper presents the noise conducted electromagnetic emission spectrum from compact fluorescent lamp. It is also presented a proposal to reduce noise level. The tests were made on typical 15 W and 18 W compact fluorescents lamps with electronic self-ballast. The measured conducted electromagnetic interference (EMI) emission spectrum and the proposal circuit to reduce the noise level for three lamps manufacturers are presented. The test setup is referred to CISPR-15 standard, covering the frequency between 9 kHz to 30 MHz. The measured results for the lamps with and without the proposal filter, to reduce the conducted EMI, are presented.
  • Keywords
    electromagnetic interference; fluorescent lamps; lamp accessories; compact fluorescents lamps; conducted electromagnetic interference emission spectrum; conducted interference reduction; electronic self-ballast; frequency 9 kHz to 30 MHz; power 15 W; power 18 W; Automatic testing; Circuit noise; Circuit testing; Electromagnetic interference; Electromagnetic measurements; Electronic equipment testing; Fluorescent lamps; Noise level; Noise measurement; Proposals;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (APEMC), 2010 Asia-Pacific Symposium on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-5621-5
  • Type

    conf

  • DOI
    10.1109/APEMC.2010.5475650
  • Filename
    5475650