Title :
Advanced arrhythmia interpretation by batch driven postprocessing of QRS annotations and ST-values as obtained with a commercial Holter analyzer
Author :
Janssen, M.J.A. ; Swenne, C.A.
Author_Institution :
Dept. of Cardiology, Univ. Hospital, Leiden, Netherlands
Abstract :
Four sets of MS-DOS file processing modules have been developed for the purpose of batch processing of Holter data: (1) HOLTER modules, that convert QRS, STT, and diary files as produced by commercial Holter systems to a standardized format; (2) CENSOR modules, being queries to the standardized QRS files; (3) TABULA modules, processing tabular data in a comma-separated value format extended with a special time format and performing many operations; and (4) UTILITY modules, for batch laser printer plotting, among other functions. HOLTER and CENSOR modules are dedicated to Holter data processing. TABULA and UTILITY modules can be used in any research environment. With the modules, a variety of research problems can be solved by simple writing and execution of batch files
Keywords :
computerised signal processing; electrocardiography; medical diagnostic computing; CENSOR modules; MS-DOS file processing modules; QRS annotations; ST-values; TABULA modules; UTILITY modules; advanced arrhythmia interpretation; batch driven postprocessing; batch laser printer plotting; comma-separated value format; commercial Holter analyzer; research problems; Cardiology; Computer aided manufacturing; Data processing; Hospitals; Morphology; Pacemakers; Printers; Spectral analysis; Statistical analysis; Writing;
Conference_Titel :
Computers in Cardiology 1991, Proceedings.
Conference_Location :
Venice
Print_ISBN :
0-8186-2485-X
DOI :
10.1109/CIC.1991.169141