DocumentCode
2514831
Title
Quantitative VOI-based Analysis of Template-guided Attenuation Correction in 3D Brain PET
Author
Montandon, Marie-Louise ; Zaidi, Habib
Author_Institution
Div. of Nucl. Medicine, Geneva Univ. Hosp.
Volume
6
fYear
2006
fDate
Oct. 29 2006-Nov. 1 2006
Firstpage
3326
Lastpage
3330
Abstract
A transmission template-guided attenuation correction method was recently proposed and validated in comparison to transmission-based attenuation correction using voxelwise SPM analysis of clinical data. In contrast to brain activation studies, brain PET research studies often involve absolute quantification. As the assessment was carried out by a SPM group analysis alone, validation as to how such quantification can be affected by the two methods needed to be performed to demonstrate how the proposed method performs individually, particularly for diagnostic applications or individual quantification. In this study, we assess the quantitative accuracy of this method using automated volume of interest (VOI)-based analysis by means of the BRASS software for automatic fitting and quantification of functional brain images. There is a very good correlation (R2 = 0.91) between the Atlas-guided and measured transmission-guided attenuation correction techniques and the regression line agreed well with the line of identity (slope = 0.96). The mean absolute relative difference between the two methods for all VOIs across the whole population is 2.3% whereas the maximum difference is less than 7%. No proof of statistically significant differences could be verified for all regions. These encouraging results provide further confidence in the adequacy of the proposed approach demonstrating its performance particularly for research studies or diagnostic applications involving quantification.
Keywords
brain; medical image processing; positron emission tomography; 3D brain PET; BRASS software; VOI based analysis; brain activation study; brain image; transmission template guided attenuation correction method; volume of interest based analysis; voxelwise SPM analysis; Attenuation measurement; Brain; Image analysis; Measurement standards; Nuclear and plasma sciences; Positron emission tomography; Protocols; Scanning probe microscopy; Standards development; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location
San Diego, CA
ISSN
1095-7863
Print_ISBN
1-4244-0560-2
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2006.353717
Filename
4179759
Link To Document