• DocumentCode
    2515049
  • Title

    First Human Brain Images of the jPET-D4 Using 3D OS-EM with a Pre-computed System Matrix

  • Author

    Yamaya, Taiga ; Yoshida, Eiji ; Kitamura, Keishi ; Obi, Takashi ; Tanimoto, Katsuyuki ; Yoshikawa, Kyosan ; Ito, Hiroshi ; Murayama, Hideo

  • Author_Institution
    Molecular Imaging Center, National Inst. of Radiol. Sci., Chiba
  • Volume
    6
  • fYear
    2006
  • fDate
    Oct. 29 2006-Nov. 1 2006
  • Firstpage
    3384
  • Lastpage
    3387
  • Abstract
    The JPET-D4 is a novel brain PET scanner which aims to achieve not only high spatial resolution but also high scanner sensitivity by measuring 4-layer depth-of-interaction (DOI) information. In this work, we present software strategies for 3D image reconstruction and imaging performance of the JPET-D4 prototype. The dimensions of a system matrix for the JPET-D4 become 4 billion (coincidence pairs) times 5 million (image elements) when a 25 cm diameter FOV is sampled by a 1.53 mm3 voxel. The size of the system matrix is estimated at 142 peta (P) byte with the accuracy of 8 byte per element. The on-the-fly calculation is usually used to deal with a huge system matrix. However we can not avoid the extension of calculation time when we improve the accuracy of system modeling. In this work, we proposed an alternative approach based on the pre-calculation of the system matrix. The 142 P byte system matrix was compressed into 13.4GB by (1) reducing zero elements, (2) applying the 3D-expanded DOI compression method, (3) factorizing with respect to ring differences and (4) restricting the maximum ring difference to 54 (with only 10% loss of the number of LORs). Histogram-based 3D OSEM based on geometrical system modeling was implemented. After evaluating basic imaging performance though phantom experiments, a normal volunteer was scanned and the first human brain images were obtained.
  • Keywords
    brain; expectation-maximisation algorithm; image reconstruction; medical computing; medical image processing; positron emission tomography; 3D OSEM; 3D expanded DOI compression method; 3D image reconstruction; JPET-D4; brain PET scanner; depth-of-interaction information; geometrical system modeling; human brain image; imaging performance; on-the-fly calculation; precomputed system matrix; scanner sensitivity; Brain; High-resolution imaging; Humans; Image reconstruction; Imaging phantoms; Modeling; Positron emission tomography; Software performance; Software prototyping; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2006. IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1095-7863
  • Print_ISBN
    1-4244-0560-2
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2006.353728
  • Filename
    4179770