Title :
Targeted Fully 3D Monte Carlo Reconstruction in SPECT
Author :
Bitar, Ziad El ; Petegnief, Yolande ; Hill, David ; Breton, Vincent ; Buvat, Irène
Author_Institution :
Lab. of Corpuscular Phys., Blaise Pascal Univ., Aubiere
fDate :
Oct. 29 2006-Nov. 1 2006
Abstract :
Fully 3D Monte-Carlo (F3DMC) reconstruction consists in calculating a fully 3D object-specific system matrix using Monte-Carlo simulations and inverting it using an iterative approach. To reduce the large amount of disk space required by this approach, we derived a targeted F3DMC approach (TF3DMC) in which the volume to be reconstructed is irregularly sampled, so that pre-identified functional regions of interest are reconstructed using fine sampling while regions with non-specific activity or without any particular interest are coarsely sampled. This method was assessed using simulated and real SPECT data of a phantom filled with Tc99m. The GATE Monte-Carlo simulator was considered to simulate the phantom data and to calculate the system matrices needed for the reconstruction of the simulated and of the real SPECT data. Activity ratios measured in TF3DMC images were compared with those measured on F3DMC and OSEM images corrected for scatter, attenuation and detector response function. TF3DLMC yielded errors less than 10% in activity ratio estimates in hot regions, while errors with quantitative OSEM were between -21% and -3%. The space needed to store the system matrix was divided by a factor from 3.5 to 9.4 compared to F3DMC, for similar or even better accuracy in activity ratio estimates. These results suggest that TF3DMC can be made practical and outperforms F3DMC and OSEM in terms of quantitative accuracy.
Keywords :
Monte Carlo methods; image reconstruction; iterative methods; phantoms; single photon emission computed tomography; OSEM images; SPECT; Tc99m; attenuation; detector response function; fully 3D Monte Carlo reconstruction; fully 3D object specific system matrix; iterative method; phantom; targeted F3DMC approach; Attenuation measurement; Detectors; Image reconstruction; Imaging phantoms; Iterative methods; Monte Carlo methods; Object detection; Sampling methods; Single photon emission computed tomography; Solid modeling;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2006.353734