DocumentCode :
2516554
Title :
Simulation and Design of Orthogonal Capacitive Strip CdZnTe Detectors
Author :
Montemont, G. ; Gentet, M.-C. ; Monnet, O. ; Rustique, J. ; Verger, L.
Author_Institution :
CEA-LETI, Grenoble
Volume :
6
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
3762
Lastpage :
3766
Abstract :
Orthogonal strip detectors are single-carrier devices that allow reduction of the amount of read-out channels while obtaining a good spatial resolution. They are especially interesting for low count rate imaging applications like gamma-ray medical imaging. Nevertheless, applying a bias voltage between X and Y strips is necessary in order to localize correctly the interactions. Unfortunately, this bias voltage induces a leakage current, thus generating an unwanted shot noise. We propose in this paper a new setup using capacitive contacts, which suppresses leakage currents between collecting and non-collecting strips. In this paper, we first briefly present the state-of-the-art relative to coplanar grid and strip detectors, their advantages and their drawbacks. In a second part, we will focus on the theoretical background of the capacitive contact. In a third part, a simulation study of the electrode geometry is reported. Thanks to the spectral approach, we have computed the 3D applied and weighting electric fields, bulk resistances and capacitances for various geometries of the design. Afterwards, we have used these data to simulate pulse waveforms and study the associated electronics. Finally the fabrication of the devices is presented and our first experimental results are reported. As a conclusion, we will discuss the interests and the limitations of this kind of devices.
Keywords :
cadmium compounds; capacitive sensors; gamma-ray detection; readout electronics; semiconductor counters; CdZnTe; SPECT imager; bias voltage; bulk capacitances; bulk resistances; capacitive CdZnTe detector; capacitive contacts; coplanar grid detector; gamma-ray detector; gamma-ray medical imaging; leakage current; low count rate imaging; orthogonal strip detector; read-out channels; spatial resolution; unwanted shot noise; weighting electric field; Biomedical imaging; Computational modeling; Detectors; Leakage current; Medical simulation; Noise generators; Optical imaging; Spatial resolution; Strips; Voltage; CdZnTe; SPECT imager; capacitive contact; coplanar grid detector; gamma-ray detectors; strip detector;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.353812
Filename :
4179854
Link To Document :
بازگشت