• DocumentCode
    2516777
  • Title

    A comparison between void and electrical treeing discharges in polyethylene

  • Author

    Suwarno

  • Author_Institution
    Dept. of Electr. Eng., Bandang Inst. of Technol., Indonesia
  • Volume
    1
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    493
  • Abstract
    Partial discharges (PD) in void and electrical treeing were measured by using a computer aided measurement system. The results showed that the magnitude and the occurrence of PDs in voids were different from that of treeing PDs. Pulse-sequence-analysis and the PD distribution revealed the role of the instantaneous and the time derivative of the applied voltage on the magnitude and the occurrence of PDs. The experimental results also showed that a conventional Whitehead equivalent circuit for a void PD can not be used for a treeing PD. An equivalent circuit for treeing PD is proposed
  • Keywords
    equivalent circuits; insulation testing; partial discharges; polyethylene insulation; trees (electrical); voids (solid); Whitehead equivalent circuit; applied voltage; computer aided measurement system; electrical treeing discharges; equivalent circuit; partial discharges; polyethylene; pulse-sequence-analysis; void discharges; Application software; Dielectric materials; Dielectric measurements; Electric variables measurement; Equivalent circuits; Partial discharges; Polyethylene; Solids; Trees - insulation; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 2000. Proceedings of the 6th International Conference on
  • Conference_Location
    Xi´an
  • Print_ISBN
    0-7803-5459-1
  • Type

    conf

  • DOI
    10.1109/ICPADM.2000.875737
  • Filename
    875737