DocumentCode :
2518020
Title :
A linearly optical scanning mirror for real-time imaging of optical coherence tomography
Author :
Lin, Chien-Hua ; Ti-Kuang Hou, M. ; Hsu, I-Jen ; Dong-Cherng Wen
Author_Institution :
Dept. of Mech. Eng., China Inst. of Technol.
fYear :
2005
fDate :
1-4 Aug. 2005
Firstpage :
59
Lastpage :
60
Abstract :
A linearly optical scanning mirror serving as the reference mirror in OCT was developed. The 3mm aperture mirror was measured to have resonant frequency of 570Hz and 768mum stroke, which enable real-time imaging of OCT
Keywords :
image scanners; mirrors; optical scanners; optical tomography; 3 mm; 570 Hz; aperture mirror; optical coherence tomography; optical scanning mirror; real-time imaging; resonant frequency; Assembly; Biomedical imaging; Biomedical optical imaging; High-resolution imaging; Laser beam cutting; Mirrors; Optical imaging; Resonant frequency; Tomography; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Optical MEMS and Their Applications Conference, 2005. IEEE/LEOS International Conference on
Conference_Location :
Oulu
Print_ISBN :
0-7803-9278-7
Type :
conf
DOI :
10.1109/OMEMS.2005.1540075
Filename :
1540075