DocumentCode
2518277
Title
Partial discharge characteristics and tree propagation in artificially-simulated tree channel
Author
Kaneiwa, Hiroshi ; Suzuoki, Yasuo ; Mizutani, Teruyoshi
Author_Institution
Nagoya Univ., Japan
fYear
1998
fDate
22-25 Jun 1998
Firstpage
123
Lastpage
126
Abstract
In an attempt to clarify the mechanism of electrical treeing degradation and tree propagation, partial discharge (PD) characteristics in an artificially-simulated tree channel in a low-density polyethylene (LDPE) sample were investigated. The PD´s formed PD pulse trains whose magnitude changed with time. In the samples where tree propagation was seen at the tip of the artificial channel, pulse trains with large PD magnitude sometimes occurred and the region of light emission reached the vicinity of the channel tip before tree propagation. In the samples where tree propagation was not seen, the region of light emission due to PD did not reach the channel tip. These results suggest that tree propagation takes place when PD´s with large magnitude and long luminous region occur in an artificial channel and damage the channel tip
Keywords
insulation testing; partial discharges; polyethylene insulation; trees (electrical); 3 kV; 6 kV; LDPE; PD characteristics; PD pulse trains; artificially-simulated tree channel; channel tip; electrical treeing degradation; light emission; long luminous region; low-density polyethylene; partial discharge characteristics; tree propagation; Charge measurement; Degradation; Optical microscopy; Optical propagation; Partial discharges; Polyethylene; Pulse measurements; Tungsten; Voltage; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Conduction and Breakdown in Solid Dielectrics, 1998. ICSD '98. Proceedings of the 1998 IEEE 6th International Conference on
Conference_Location
Vasteras
Print_ISBN
0-7803-4237-2
Type
conf
DOI
10.1109/ICSD.1998.709241
Filename
709241