Abstract :
A reliable and consistent measure of quality of electric power is essential for diagnostics and mitigation of many power system problems. The authors describe a prototype designed and developed at IREQ. The system produces a report on the following degradation in power quality: root-mean-square (RMS) voltage variations from 2 per day to 0.5 Hz; RMS voltage variations from 0.5 Hz to 25 Hz; unbalance in fundamental component of voltage; harmonics in voltages and currents up to 300 Hz; and transient variations slower than 50 microseconds. The system is based on a laptop PC with a custom interface to the power system, located in a similar size briefcase for easy portability
Keywords :
automatic test equipment; electrical faults; fault diagnosis; harmonics; microcomputer applications; portable instruments; power measurement; power system measurement; power system transients; 0.5 Hz to 25 Hz; 300 Hz; 50 ns; IREQ; RMS voltage variations; briefcase; custom interface; diagnostics; harmonics; laptop PC; portability; portable integrated power quality measurement; power system; prototype; transient variations; unbalance; Degradation; Electric variables measurement; Power measurement; Power quality; Power system harmonics; Power system measurements; Power system reliability; Power system transients; Prototypes; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 1993. IMTC/93. Conference Record., IEEE
Conference_Location :
Irvine, CA
Print_ISBN :
0-7803-1229-5
Type :
conf
DOI :
10.1109/IMTC.1993.382563
Filename :
382563
Link To Document :
بازگشت