• DocumentCode
    2519791
  • Title

    FROM GIGABYTES TO BYTES: AUTOMATED DENOISING AND FEATURE IDENTIFICATION IN ELECTRON TOMOGRAMS OF INTACT BACTERIAL CELLS

  • Author

    Narasimha, Rajesh ; Aganj, Iman ; Borgnia, Mario ; Sapiro, Guillermo ; McLaughlin, Steven ; Milne, Jacqueline ; Subramaniam, Sriram

  • fYear
    2007
  • fDate
    12-15 April 2007
  • Firstpage
    304
  • Lastpage
    307
  • Abstract
    Advances in automated data acquisition in electron tomography have led to an explosion in the amount of data that can be obtained about the spatial architecture of a variety of biologically and medically relevant objects with resolutions in the "nano" range of 10-1000 nm. The development of methods to automatically analyze the vast amounts of information contained in these tomograms is a major challenge since the electron tomograms are intrinsically very noisy. A fundamental step in the automatic analysis of large amounts of data for statistical inference is to segment relevant 3D features in cellular tomograms. Procedures for segmentation must work robustly and rapidly in spite of the low signal to noise ratios inherent to biological electron microscopy. This work first evaluates various non-linear denoising techniques on tomograms recorded at cryogenic temperatures. Using datasets of bacterial tomograms as an example, we demonstrate that non-linear diffusion techniques significantly improve the fidelity of automated feature extraction. Our approach represents an important step in automating the efficient extraction of useful information from large datasets in biological tomography, and facilitates the overall goal of speeding up the process of reducing gigabyte-sized tomograms to relevant byte-sized data.
  • Keywords
    feature extraction; image segmentation; medical image processing; microorganisms; tomography; automated data acquisition; bacterial cells; denoising; electron tomograms; feature extraction; segmentation; Data acquisition; Electrons; Explosions; Information analysis; Microorganisms; Noise reduction; Noise robustness; Signal to noise ratio; Spatial resolution; Tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Imaging: From Nano to Macro, 2007. ISBI 2007. 4th IEEE International Symposium on
  • Conference_Location
    Arlington, VA
  • Print_ISBN
    1-4244-0672-2
  • Electronic_ISBN
    1-4244-0672-2
  • Type

    conf

  • DOI
    10.1109/ISBI.2007.356849
  • Filename
    4193283