• DocumentCode
    2519792
  • Title

    The starter-generating installation based on IGBT - inverters

  • Author

    Stennikov, A.A. ; Kharitonov, S.A. ; Rodikov, G.G. ; Zinoviev, G.S. ; Berestov, V.M.

  • Author_Institution
    Novosibirsk State Tech. Univ., Russia
  • fYear
    2002
  • fDate
    23-26 Sept. 2002
  • Firstpage
    252
  • Lastpage
    256
  • Abstract
    The starter-generating installation based on voltage source inverters for the gas pump stations and wind power installation is described, the electromagnetic processes are considered and the analytical ratio for the convertible mode of operations of the voltage source inverter are given. The results of the theory are checked up by modeling on the computer with program PARUS.
  • Keywords
    insulated gate bipolar transistors; invertors; natural gas technology; starting; synchronous generators; wind power plants; IGBT inverter; PARUS program; computer model; electromagnetic process; gas pump station; starter-generating installation; voltage source inverter; wind power installation; Character generation; Chromium; Filters; Insulated gate bipolar transistors; Load flow; Magnetic variables control; Power generation; Pulse width modulation; Pulse width modulation inverters; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Instrument Engineering Proceedings, 2002. APEIE 2002. 2002 6th International Conference on Actual Problems of
  • Print_ISBN
    0-7803-7361-8
  • Type

    conf

  • DOI
    10.1109/APEIE.2002.1075835
  • Filename
    1075835