DocumentCode :
2520492
Title :
Investigation on sensor array in large vertical storage tank bottom inspection using AE methods
Author :
Liying, Sun ; Yibo, Li
Author_Institution :
Dept. of Energy & Mech. Eng., Tianjin Inst. of Urban Constr., Tianjin, China
fYear :
2011
fDate :
23-25 May 2011
Firstpage :
2838
Lastpage :
2842
Abstract :
Dynamic defects on floor of large Aboveground Storage Tanks (AST) may lead to serious tank accidents and loss of properties. Acoustic emission (AE) has been used in storage tank floor inspection to rank maintenance priority in recent years before using other non-destructive methods, such as magnetic flux leakage, eddy current and ultrasonic. There are both economical and environmental benefits by not emptying and cleaning large storage tanks. This paper mainly covers principle of corrosion condition inspection for storage tank floor using AE method and investigation on AE sensors used in the test. Frequency, number, and installation requirements including height, space, and coupling agent are investigated in detail. Nielsen-Hsu pencil break calibration process for AE inspection channel is introduced. In the end, an AE inspection was carried out on a 20000m3 AST containing crude oil. Optimized BP Neural network is used in pattern recognition to remove electro-magnetic noise and mechanical fiction noise.
Keywords :
acoustic emission testing; backpropagation; computerised instrumentation; corrosion; crude oil; environmental factors; flaw detection; industrial accidents; inspection; maintenance engineering; neural nets; noise abatement; nondestructive testing; sensor arrays; tanks (containers); Nielsen-Hsu pencil break calibration process; aboveground storage tank floor defects; acoustic emission; corrosion condition inspection; electromagnetic noise removal; environmental benefit; large vertical storage tank bottom inspection; maintenance priority; mechanical fiction noise removal; nondestructive method; optimized BP neural network; pattern recognition; sensor array; tank accidents; Acoustic emission; Corrosion; Floors; Inspection; Monitoring; Storage tanks; AE; AST; Sensor; Tank floor inspection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control and Decision Conference (CCDC), 2011 Chinese
Conference_Location :
Mianyang
Print_ISBN :
978-1-4244-8737-0
Type :
conf
DOI :
10.1109/CCDC.2011.5968695
Filename :
5968695
Link To Document :
بازگشت