DocumentCode
2521016
Title
Study of Key Parameters of Thermal Flow Reversal Reaction
Author
Gao Zhenqiang ; Liu Ruixiang ; Liu Yongqi
Author_Institution
Sch. of Transp. & Vehicle Eng., Shandong Univ. of Technol., Zibo, China
fYear
2009
fDate
11-13 June 2009
Firstpage
1
Lastpage
3
Abstract
Thermal flow reversal reaction (TFRR) is a proper method to deal with lean methane. Heat recovery efficiency, peak temperature and switching time are key parameters of TFRR. Experiments were carried out to study these parameters. The results show that: the quality of heat energy loses in the process of heat transfer; the peak temperature could be controlled by changing of switching time; withdraw hot gas from the end of reactor is not proper for energy output.
Keywords
chemical reactors; heat losses; heat recovery; heat transfer; heat energy loses; heat recovery efficiency; heat transfer; hot gas; lean methane; peak temperature; switching time; thermal flow reversal reaction; Ceramics; Feeds; Global warming; Heat recovery; Heat transfer; Inductors; Oxidation; Temperature control; Temperature sensors; Valves;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering , 2009. ICBBE 2009. 3rd International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-2901-1
Electronic_ISBN
978-1-4244-2902-8
Type
conf
DOI
10.1109/ICBBE.2009.5163448