DocumentCode :
2521285
Title :
Stability measurements between Hg+ lite 12-pole clocks
Author :
Prestage, J.D. ; Chung, S. ; Burt, E. ; Maleki, L. ; Tjoelker, R.L.
Author_Institution :
Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA, USA
fYear :
2002
fDate :
2002
Firstpage :
459
Lastpage :
462
Abstract :
We describe frequency stability measurements of two Hg-ion clocks based upon linear 12-pole shuttle ion traps. The inter-comparison was carried out over several multi-day intervals with the short-term stability of each clock better than 2×10-13 at 1 second. Longer-term stability as good as 3×10-16 was demonstrated for these clocks.
Keywords :
Doppler shift; atomic clocks; frequency stability; frequency standards; mercury (metal); 1 s; Hg+; frequency pulling mechanism; frequency stability measurements; ion clouds; linear 12-pole shuttle ion traps; linear ion trap atomic clocks; multi-day intervals; second-order Doppler shift; short-term stability; Clocks; Electromagnetic heating; Fluorescence; Frequency measurement; Mercury (metals); Optical pumping; Particle beam optics; Resonance; Stability; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Frequency Control Symposium and PDA Exhibition, 2002. IEEE International
Print_ISBN :
0-7803-7082-1
Type :
conf
DOI :
10.1109/FREQ.2002.1075926
Filename :
1075926
Link To Document :
بازگشت