DocumentCode :
2522369
Title :
COMPARISON OF RADIATIVE TRANSPORT, MONTE CARLO, AND DIFFUSION FORWARD MODELS FOR SMALL ANIMAL OPTICAL TOMOGRAPHY
Author :
Rasmussen, John C. ; Pan, Tianshu ; Joshia, Amit ; Wareing, Todd ; McGhee, John ; Sevick-Muraca, Eva M.
Author_Institution :
Dept. of Radiol., Baylor Coll. of Med., Houston, TX
fYear :
2007
fDate :
12-15 April 2007
Firstpage :
824
Lastpage :
827
Abstract :
Herein we present a comparison of Monte Carlo, radiative transport (RT), and diffusion based forward models for implementation into small animal optical tomography algorithm. The simulations show that the unique RT solver can accurately predict the time-dependent propagation of excitation and emission photons in diffuse as well as transport limited systems. Furthermore, the need for the accurate modeling of incident excitation illumination and the acceptance angle of the detector is demonstrated
Keywords :
Monte Carlo methods; bio-optics; biodiffusion; biomedical optical imaging; drugs; optical tomography; patient treatment; Monte Carlo models; biodistribution; detector acceptance angle; diffusion forward models; drug candidates; emission photons; excitation photons; incident excitation illumination; radiative transport; small animal optical tomography; therapeutic efficacy; time-dependent propagation; transport limited systems; Animals; Biomedical optical imaging; Detectors; Equations; Fluorescence; Monte Carlo methods; Optical propagation; Optical scattering; Stimulated emission; Tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Imaging: From Nano to Macro, 2007. ISBI 2007. 4th IEEE International Symposium on
Conference_Location :
Arlington, VA
Print_ISBN :
1-4244-0672-2
Electronic_ISBN :
1-4244-0672-2
Type :
conf
DOI :
10.1109/ISBI.2007.356979
Filename :
4193413
Link To Document :