• DocumentCode
    2522812
  • Title

    Parameters affecting the static electrification of aged transformer oils

  • Author

    N´Cho, J.S. ; Fofana, I. ; Beroual, A.

  • Author_Institution
    AMPERE, Ecole Centrale de Lyon, Ecully, France
  • fYear
    2011
  • fDate
    16-19 Oct. 2011
  • Firstpage
    571
  • Lastpage
    574
  • Abstract
    In this contribution, experimental investigations onto the factors affecting the static electrification of aged transformer oils are undertaken. The effect of aging byproducts (as assessed by Dissolved Decay products, Turbidity, Interfacial Tension and Acid number) of the oil on the streaming current is reported. The results indicate that the electrification currents generally increase with aging by-products of oil. The sign, the amplitude and the time constant of the electrification currents are also affected. The influence of each “impurity” is emphasized and discussed.
  • Keywords
    transformer oil; acid number; aged transformer oil static electrification; aging byproduct effect; dissolved decay products; electrification currents; interfacial tension; oil aging by-products; Aging; Current measurement; Insulation; Leakage current; Oils; Power transformer insulation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena (CEIDP), 2011 Annual Report Conference on
  • Conference_Location
    Cancun
  • ISSN
    0084-9162
  • Print_ISBN
    978-1-4577-0985-2
  • Type

    conf

  • DOI
    10.1109/CEIDP.2011.6232721
  • Filename
    6232721