DocumentCode :
2523494
Title :
Choosing diagnostic tests to monitor stator insulation in critical motors
Author :
Stranges, Meredith K. W. ; Ul Haq, Saeed ; Vouk, Alfred O.
Author_Institution :
GE Energy Manage., Peterborough, ON, Canada
fYear :
2012
fDate :
24-26 Sept. 2012
Firstpage :
1
Lastpage :
6
Abstract :
The petrochemical industry has increasing interest in condition monitoring of stator winding insulation during service. Factory acceptance specifications developed from the American Petroleum Institute (API) standards often require a PD and/or power factor tip-up (PFTU) test for brand new windings as a factory acceptance test before installation machine is installed. Petrochemical industry users often employ partial discharge (PD) detection systems for condition assessment of critical motors, but the use of the PFTU test as a periodic evaluation technique is less popular. Specialized resources are needed to perform these tests at the factory and in the field, imposing different technical demands and requiring expert data interpretation to ensure value for the end user. PD and PFTU may serve as complementary techniques and are most useful when data are trended through the machine winding service life. Both types of measurement depend on stator winding geometry, insulating materials, insulation system construction and operating environment. This paper explains the PFTU and PD tests, describes considerations for set up and execution of measurements for factory acceptance tests and installed machines, and explores technical considerations to define an appropriate test regime to monitor insulation condition. Examples of PD and PFTU test data from factory acceptance of new stator windings and on-site measurements of installed machines are discussed.
Keywords :
condition monitoring; electric motors; insulating materials; insulator testing; machine insulation; machine testing; partial discharge measurement; petrochemicals; power factor; stators; API standards; American Petroleum Institute standards; PD detection systems; PD tests; PFTU test; PFTU test data; condition monitoring; critical motor condition assessment; diagnostic tests; factory acceptance specifications; factory acceptance test; insulating materials; machine winding service life; on-site measurements; partial discharge detection systems; periodic evaluation technique; petrochemical industry; power factor tip-up test; stator insulation monitoring; stator winding geometry; stator winding insulation; insulation; partial discharge; power factor tip-up; stator winding; tan delta; testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Petroleum and Chemical Industry Technical Conference (PCIC), 2012 Record of Conference Papers Industry Applications Society 59th Annual IEEE
Conference_Location :
Chicago, IL
ISSN :
0090-3507
Print_ISBN :
978-1-4673-0924-0
Type :
conf
DOI :
10.1109/PCICON.2012.6549647
Filename :
6549647
Link To Document :
بازگشت