DocumentCode :
2523956
Title :
Charge injection studies on XLPE surfaces exposed to partial discharges
Author :
Garcia-Colon, V.R.
Author_Institution :
Inst. de Investig. Electr., Morelos, Mexico
fYear :
2011
fDate :
16-19 Oct. 2011
Firstpage :
808
Lastpage :
811
Abstract :
Metallic electrodes covered by an on-site deposited XLPE films were annealed to release tribologic stresses and then exposed to Partial Discharge (PD) action. After exposure, time evolution of the remaining charge profile was investigated using a high spatial resolution capacitive probe. The results demonstrate a correlation between charge profile and partial discharge by-products formation. Furthermore, homo and hetero charges appear after the by-products were removed from the surface using different solvents. A strong negative charge injection is measured when a spot increases its degradation and evolves into a failure. Alteration of charge profiles changes were investigated using different degradation atmospheres including nitrogen and air. Studies performed on XLPE films allowed to correlate humidity, present during the partial discharge exposition, and PD magnitude, PD repetition rate, by-products formation and charge profile.
Keywords :
XLPE insulation; electrodes; partial discharges; polymer films; solvents (industrial); PD; XLPE film deposition; XLPE surface; annealing; charge profile; heterocharge; high spatial resolution capacitive probe; homocharge; metallic electrode; negative charge injection measurement; partial discharge; solvent; time evolution; tribologic stress; Atmosphere; Degradation; Electrodes; Humidity; Partial discharges; Probes; Spatial resolution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena (CEIDP), 2011 Annual Report Conference on
Conference_Location :
Cancun
ISSN :
0084-9162
Print_ISBN :
978-1-4577-0985-2
Type :
conf
DOI :
10.1109/CEIDP.2011.6232779
Filename :
6232779
Link To Document :
بازگشت