• DocumentCode
    2524806
  • Title

    An experimental investigation of the geometric parameters on the performance for the counter-flow vortex tubes

  • Author

    Azeez, N.T. ; Al-Barwari, R.R. ; Talabani, Z.J.

  • Author_Institution
    Mech. Eng. Dept., Salahaddin Univ. - Hawler, Erbil, Iraq
  • fYear
    2010
  • fDate
    10-12 Sept. 2010
  • Firstpage
    467
  • Lastpage
    470
  • Abstract
    In this paper the design geometric parameters and performance of the vortex tube, used as a cooling and heating device of high efficiency is investigated experimentally, it was carried out on the counter-flow vortex rig, especially designed for the present study covering all tests. The effect of cold end orifice diameters and length to diameters ratio, on the performance of a counter flow vortex tube on the overall energy separation , by using various (L/D) and cold end orifice diameters with various inlet pressure and setting hot outlet by fixing inlet temperature . The results show a pronounced influence of vortex tube (L = 180 mm), on the energy separation performance. The results also show that the maximum value of energy separation was always reachable at cold air mass ratio (μc = 0.6), irrespective of the cold end orifice diameter and the inlet pressure. The results are compared with the previous studies; it has shown a good agreement and compatible results with them.
  • Keywords
    cooling; orifices (mechanical); pipes; vortices; cold air mass ratio; cold end orifice diameter; cooling device; counter-flow vortex tubes; energy separation; geometric parameters; heating device;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechanical and Electrical Technology (ICMET), 2010 2nd International Conference on
  • Conference_Location
    Singapore
  • Print_ISBN
    978-1-4244-8100-2
  • Type

    conf

  • DOI
    10.1109/ICMET.2010.5598403
  • Filename
    5598403