DocumentCode :
2526925
Title :
Determining optimum load impedance for a noisy active 2-port network.
Author :
Ciccognani, Walter ; Giannini, Franco ; Limiti, Ernesto ; Longhi, Patrick Ettore ; Serino, Antonio
Author_Institution :
Univ. di Roma Tor Vergata, Rome
fYear :
2007
fDate :
8-10 Oct. 2007
Firstpage :
595
Lastpage :
598
Abstract :
The role of the impedance load when dealing with noisy two port networks is investigated. Its value acts directly on input and output return losses (IRL and ORL) that can be simultaneously achieved once input load has been fixed to an arbitrary value. A novel design chart, obtained after examining constant mismatch circles, is introduced, where optimum tradeoff between IRL and ORL is promptly identified. The role of degenerative source feedback is highlighted to improve IRL/ORL trade-off.
Keywords :
microwave amplifiers; constant mismatch circles; degenerative source feedback; design chart; microwave amplifiers; noisy active 2-port network; optimum load impedance; Active noise reduction; Impedance matching; Integrated circuit noise; Microwave devices; Microwave integrated circuits; Noise figure; Output feedback; Performance gain; Reflection; Stability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Integrated Circuit Conference, 2007. EuMIC 2007. European
Conference_Location :
Munich
Print_ISBN :
978-2-87487-002-6
Type :
conf
DOI :
10.1109/EMICC.2007.4412783
Filename :
4412783
Link To Document :