• DocumentCode
    2526981
  • Title

    A comparative study on the precision of various six-port correlators

  • Author

    Ghannouchi, Fadhel M. ; Bosisio, Renato G.

  • Author_Institution
    Dept. de Genie Electr., Ecole Polytech. de Montreal, Que., Canada
  • fYear
    1988
  • fDate
    20-22 Apr 1988
  • Firstpage
    256
  • Lastpage
    259
  • Abstract
    A detailed analysis of the accuracy of complex reflection coefficient (Γ) measurements using the six-port technique is presented. The expression for the relative error in amplitude measurement and the absolute error in phase measurement of the complex reflection coefficient, due to power-reading errors, are derived in the worst-case situation using both the basic six-port and sensitivity analysis theories. The measurement precision of any point in the Smith chart is obtained by reference to lines of constant error (amplitude and phase) drawn on the Smith chart for various proposed six-port correlators (junctions). G.F. Engen´s (1977) six-port design provides the best overall accuracy in the measurement of Γ
  • Keywords
    measurement errors; microwave reflectometry; network analysers; Smith chart; absolute error; amplitude measurement; complex reflection coefficient; constant error; measurement errors; phase measurement; power-reading errors; relative error; six-port correlators; Calibration; Correlators; Detectors; Dynamic range; Microwave measurements; Noise measurement; Phase measurement; Power measurement; Proposals; Reflection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1988. IMTC-88. Conference Record., 5th IEEE
  • Conference_Location
    San Diego, CA
  • Type

    conf

  • DOI
    10.1109/IMTC.1988.10861
  • Filename
    10861