Title :
Rapid detection of bladder cancer using an immunoassay transistor combined with DNA-labeling technique in a microfluidic chip
Author :
Po-Yu Peng ; Wei-Chieh Hsu ; Tung-Ming Pan ; Yen-Heng Lin
Author_Institution :
Dept. of Electron. Eng., Chang Gung Univ., Taoyuan, Taiwan
Abstract :
We propose a method that can be used to quantitatively measure concentrations of protein through a semiconductor sensor with a robust signal. Measurement of protein by a semiconductor may encounter a major problem. For specifically measuring protein, an antibody is immobilized on the semiconductor sensor surface. The physical length of the antibody is around 10 nm, a distance too long to be sensed by the semiconductor sensor, which means that the following attached protein cannot be sensed. In this study, we used a bead-based immunoassay combined with the DNA strain labeling technique to overcome this issue. Protein was first captured using an antibody-coated magnetic bead. It was then labeled with a secondary antibody combined with the DNA strain. Finally, the magnetic bead with the biotarget was attracted on the sensor surface by an external magnetic field, and then the negative charges of the DNA changed the surface potential of the sensor. The concentration of protein could then be measured accordingly. The signal could be further improved by the optimization of the number of labeling DNA and the size of the magnetic bead. In addition, the semiconductor sensor was incorporated in a microfluidic chip with microvalves and a micromixer. The microfluidic procedure reduced the total measurement time to around 1 h (plate ELISA 4h). Furthermore, by changing the antibody to another type of antibody coated on the magnetic bead, the sensor could be reused to measure other types of protein. The proposed method provides a solution for the robust measurement of protein concentration through the semiconductor sensor.
Keywords :
DNA; bioMEMS; biomagnetism; biosensors; cancer; chemical sensors; lab-on-a-chip; magnetic particles; magnetic sensors; microfluidics; microsensors; microvalves; patient diagnosis; transistors; DNA strain labeling technique; antibody-coated magnetic bead; bead-based immunoassay; biotarget; bladder cancer; external magnetic field; immunoassay transistor; magnetic bead size; microfluidic chip; microfluidic procedure; micromixer; microvalves; negative charges; physical length; protein concentration measurement; rapid detection; secondary antibody; semiconductor sensor surface; sensor surface potential; size 10 nm; time 1 hr; total measurement time; DNA; Immune system; Magnetic field measurement; Magnetic semiconductors; Proteins; Semiconductor device measurement; Strain; immunoassay; magnetic bead; microfluidic; protein; sensor; transistor;
Conference_Titel :
Nano/Micro Engineered and Molecular Systems (NEMS), 2014 9th IEEE International Conference on
Conference_Location :
Waikiki Beach, HI
DOI :
10.1109/NEMS.2014.6908819