In the present work, the design and experimental set-up conditions of a micromachined accelerometer based on convection heat transfer are reviewed. The effects on sensitivity are analytically studied and allow discussion of the linearity range. They are confirmed by simulation and experimental results. With optimized experimental parameters, we achieve for the first time high-g measurements of up to 10,000 g with a thermal accelerometer.
Keywords
accelerometers; convection; micromachining; microsensors; convection heat transfer; first high-g measurement; micromachined thermal accelerometer; Acceleration; Accelerometers; Cavity resonators; Heating; Linearity; Sensitivity; Temperature sensors; Accelerometer; MEMS; convection; high-g; thermal;