Title :
Investigations into pre-discharges in a rod-plane gap under negative lightning impulse voltage
Author :
Shihab, S. ; Salm, R.J.
Author_Institution :
Dept. of Electr. Eng., Delft Univ. of Technol., Netherlands
fYear :
1988
fDate :
12-16 Sep 1988
Firstpage :
178
Abstract :
Results are reported of investigations into the influence of the space charge associated with impulse corona on the growth and direction of the leader in a rod-plane of 1.72 m with a negative-polarity lightning impulse voltage applied to the rod. The charge oscillograms show three distinct steps of 2.5, 5.0, and 8.0 μC, and these are attributed to the first corona and secondary discharges including leader development. In order to assess the effect of impulse corona space charge on the field distribution, field calculations with and without space charges were carried out using the charge simulation method. From the results of the calculations together with photographs taken of the discharge, attempts are made to explain the direction and growth of the leader in the gap
Keywords :
air; electric breakdown of gases; impulse testing; lightning protection; spark gaps; 1.72 m; charge oscillograms; charge simulation method; effect of impulse corona space charge; field calculations; field distribution; influence of space charge; leader development; leader growth; negative lightning impulse voltage; negative rod; photographs; predischarges; rod-plane gap; secondary discharges; Charge measurement; Circuits; Corona; Current measurement; Fault location; Geometry; Lightning; Space charge; Space technology; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials, 1988. Proceedings., Second International Conference on Properties and Applications of
Conference_Location :
Beijing
Type :
conf
DOI :
10.1109/ICPADM.1988.38363
Filename :
38363
Link To Document :
بازگشت