DocumentCode :
2531053
Title :
Design of wireless sensor node based on a novel hybrid chemical sensor for heavy metal monitoring
Author :
Cai, W. ; Zhao, H.X. ; Ha, D. ; Guo, H.S. ; Zhang, W. ; Wang, P.
Author_Institution :
Dept. of Biomed. Eng., Zhejiang Univ., Hangzhou, China
fYear :
2011
fDate :
5-9 June 2011
Firstpage :
2114
Lastpage :
2117
Abstract :
A wireless sensor node based on a novel hybrid chemical sensor was designed for heavy metal monitoring. The node consisted of four units that were the transducer unit, the processor unit, the communication unit and the power unit. The hybrid chemical sensor combining microelectrode arrays (MEA) and light-addressable potentiometric sensors (LAPS) on the same silicon chip was used to get redundant data about the concentrations of heavy metal and hydrogen ions in water environment. Multiple linear regression (MLR) with peak currents of Zn2+, Pb2+ and Cu2+ from MEA and equilibrium potentials of Zn2+, Pb2+, Cu2+ and H+ from LAPS as the explanatory variables and the concentrations of Zn2+, Pb2+ and Cu2+ as the response variables was modeled to improve the anti-interference ability.
Keywords :
chemical sensors; copper; hydrogen; lead; microelectrodes; monitoring; regression analysis; wireless sensor networks; zinc; Cu2+; H+; LAPS; MEA; MLR; Pb2+; WSN; Zn2+; communication unit; heavy metal monitoring; hybrid chemical sensor; light-addressable potentiometric sensors; microelectrode arrays; multiple linear regression; power unit; processor unit; wireless sensor node; Chemical sensors; Electrodes; Ions; Metals; Monitoring; Wireless communication; Wireless sensor networks; Heavy metals; Hybrid chemical sensor; LAPS; MEA; Wireless sensor node;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Solid-State Sensors, Actuators and Microsystems Conference (TRANSDUCERS), 2011 16th International
Conference_Location :
Beijing
ISSN :
Pending
Print_ISBN :
978-1-4577-0157-3
Type :
conf
DOI :
10.1109/TRANSDUCERS.2011.5969274
Filename :
5969274
Link To Document :
بازگشت