• DocumentCode
    2531520
  • Title

    Augmented heat transfer in rectangular duct with angled Z-shaped ribs

  • Author

    Pimsarn, Monsak ; Sriromreun, Parkpoom ; Promvonge, Pongjet

  • Author_Institution
    Sch. of Mech. Eng., King Mongkut´´s Inst. of Technol., Bangkok, Thailand
  • fYear
    2010
  • fDate
    2-4 June 2010
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance.
  • Keywords
    ducts; friction; heat exchangers; heat transfer; turbulence; Nusselt number; Reynolds numbers; air flow direction; friction factor; friction loss; heat exchanger; heat transfer; rectangular ducts; thermal enhancement factor; z-shape ribs; Educational institutions; Heating; Inverters; Nusselt number; angle rib; channel flow; enhanced heat transfer; rib;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy and Sustainable Development: Issues and Strategies (ESD), 2010 Proceedings of the International Conference on
  • Conference_Location
    Chiang Mai
  • Print_ISBN
    978-1-4244-8563-5
  • Type

    conf

  • DOI
    10.1109/ESD.2010.5598858
  • Filename
    5598858