• DocumentCode
    2532951
  • Title

    The study of humidity on flashover voltage characteristics for positive SI

  • Author

    Xu, Qi

  • Author_Institution
    Qinghai Electr. Power Test & Res. Inst.
  • fYear
    1988
  • fDate
    12-16 Sep 1988
  • Firstpage
    253
  • Abstract
    A description is given of the flashover characteristics (U50%) of seven typical objects over a range of atmospheric conditions. It was found that the influence of humidity on flashover voltage is different at different altitudes, when compared with respect to the IEC humidity correction factor K and China standard GB311-83. The corrected value in the geographic region studied is higher than the recommended value. The humidity correction factor suitable to the local natural atmospheric condition is given
  • Keywords
    environmental testing; flashover; humidity; insulation testing; insulators; China standard GB311-83; IEC humidity correction factor; atmospheric conditions; flashover voltage characteristics; humidity; positive standard insulation; Atmosphere; Atmospheric waves; Equations; Flashover; Humidity; IEC; Porcelain; Temperature; Testing; Voltage control;