DocumentCode :
2533943
Title :
An evaluation of network time protocol for clock synchronization in wide area measurements
Author :
Wang, Lei ; Fernandez, Javier ; Burgett, Jon ; Conners, Richard W. ; Liu, Yilu
Author_Institution :
Bradley Dept. of Electr. & Comput. Eng., Virginia Polytech. Inst. & State Univ., Blacksburg, VA
fYear :
2008
fDate :
20-24 July 2008
Firstpage :
1
Lastpage :
5
Abstract :
To study and gain a better understanding of the power system dynamics, the concept of building a frequency monitoring network (FNET) was proposed in 2000 [1] and has been realized in 2003. The FNET system consists of many high dynamic precision frequency and phasor estimation devices, also known as frequency disturbance recorders (FDR). These FDRs can be used at any 110 V or 220 V wall outlet and transmit measured data remotely via the Ethernet. The FDRs can measure power system parameters including frequency, voltage, and phase angle. There are currently more than 40 FDRs placed strategically in different locations within the North America power grids to monitor the entire power network. Furthermore, the FDRs are currently synchronized in time via a GPS receiver. This paper discusses the feasibility study of the Internet timing synchronization. The motivation for Internet timing synchronization was ignited during the research for a more portable and economical yet still highly accurate FDR design. Test results are presented from several different NTP implementation methods. Based on the correlation between time synchronization and phasor accuracy, it was concluded that the current NTP is not yet a feasible synchronization tool for accurate phasor measurement.
Keywords :
Internet; clocks; computerised monitoring; fault diagnosis; phase estimation; power engineering computing; power system measurement; synchronisation; Ethernet; GPS receiver; Internet timing synchronization; clock synchronization; frequency disturbance recorders; frequency monitoring network; network time protocol; phasor measurement; power system dynamics; wide area measurements; Clocks; Ethernet networks; Frequency estimation; Frequency synchronization; Internet; Monitoring; Power system dynamics; Protocols; Timing; Wide area measurements; Frequency Monitoring Network; Global Positioning System (GPS); Network Timing Protocol (NTP); Phasor Measurement Unit (PMU); Wide-Area Measurement; computer time synchronization; power system measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008 IEEE
Conference_Location :
Pittsburgh, PA
ISSN :
1932-5517
Print_ISBN :
978-1-4244-1905-0
Electronic_ISBN :
1932-5517
Type :
conf
DOI :
10.1109/PES.2008.4596234
Filename :
4596234
Link To Document :