• DocumentCode
    2534141
  • Title

    A three-dimensional linear model for breast tomosynthesis

  • Author

    Zhao, Bo ; Zhao, Wei

  • Author_Institution
    State Univ. of New York-Stony Brook, Stony Brook
  • fYear
    2007
  • fDate
    10-11 March 2007
  • Firstpage
    163
  • Lastpage
    164
  • Abstract
    Breast tomosynthesis alleviates the obscuring effects of overlapping breast tissue overlap in the diagnosis of breast cancer in screening mammography. In breast tomosynthesis, multiple projection images are acquired when the X-ray tube travels within a limited angular range, typically < 50deg. The projection images are reconstructed into tomographic slices that are parallel to the detector surface. Factors affecting the image quality of breast tomosynthesis include detector performance, acquisition geometry and reconstruction method. To investigate the impact of each factor, we built a three dimensional linear system model for breast tomsynthesis, validated it using experimental measurements of linear system parameters including noise power spectrum (NPS) and presampling modulation transfer function (MTF). Experiments were performed on a prototype breast tomosynthesis system equipped with an amorphous selenium (a-Se) digital mammography detector. Filtered backprojection (FBP) method was used for image reconstruction. Due to the limited angular range, the reconstructed 3D volume (512x512x40) had an anisotropic voxel size (0.085x0.085x1mm3). Scatter free uniform images were acquired for NPS analysis and an edge phantom was imaged for MTF measurements. It was found that the model agreed well with measurement, hence can be used to predict the imaging performance with different parameters and lead to optimization of breast tomosynthesis.
  • Keywords
    biological organs; cancer; image reconstruction; mammography; medical image processing; optical transfer function; optimisation; phantoms; tumours; breast cancer diagnosis; breast tomosynthesis; filtered backprojection method; image quality; image reconstruction; noise power spectrum; optimization; overlapping breast tissue; phantom; presampling modulation transfer function; screening mammography; three-dimensional linear model; Breast cancer; Breast tissue; Detectors; Image quality; Image reconstruction; Linear systems; Mammography; Surface reconstruction; Tomography; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioengineering Conference, 2007. NEBC '07. IEEE 33rd Annual Northeast
  • Conference_Location
    Long Island, NY
  • Print_ISBN
    978-1-4244-1033-0
  • Electronic_ISBN
    978-1-4244-1033-0
  • Type

    conf

  • DOI
    10.1109/NEBC.2007.4413329
  • Filename
    4413329