DocumentCode
2534337
Title
Non-invasive measurement of solute permeability of rat pial microvessels
Author
Yuan, Wei ; Lv, Yonggang ; Zeng, Min ; Fu, Bingmei M.
Author_Institution
City Coll. of the City Univ. of New York, New York
fYear
2007
fDate
10-11 March 2007
Firstpage
185
Lastpage
186
Abstract
To quantify the permeability of rat pial microvessels, we measured the apparent microvessel permeability (P) to various sized solutes. Rats (SD, 250-300 g) were anesthetized with sodium pentobarbital given subcutaneously and kept warm on a heating pad. The pial microcirculation was observed by a high numerical aperture objective lens through a section of frontoparietal bones thinned with a high-speed micro-grinder (revised method from Easton et al., 1997). During the measurement, the surface of the brain was constantly superfused with 37 degrees Celsius artificial cerebrospinal fluid. Sodium fluorescein (MW 376, Stokes radius 0.45 nm) with concentration 0.5 mg/ml or FITC-dextran (MW 4000, Stokes radius 1.8 nm) with concentration 1 mg/ml in 1% BSA mammalian Ringer, was introduced into the cerebral circulation via the ipsilateral carotid artery by a syringe pump at a constant rate of 3 ml/min. P was determined using a quantitative fluorescence imaging and analyzing method. The mean P to sodium fluorescein for 10 vessels was 1.31 (plusmn0.36 SD) times 10-6 cm/s. This value is about one-twentieth of that found in rat mesenteric microvessels, 2.6 times 10-5 cm/s (Fu and Shen, 2004). The mean P to FITC-Dextran for 5 vessels was 0.41 (plusmn 0.29 SD) times 10-6 cm/s.
Keywords
biomedical measurement; biorheology; biothermics; bone; brain; fluorescence; lenses; neurophysiology; permeability; FITC-Dextran; artificial cerebrospinal fluid; cerebral circulation; frontoparietal bones; high-numerical aperture objective lens; high-speed micro-grinder; ipsilateral carotid artery; mammalian Ringer; noninvasive measurement; quantitative fluorescence imaging; rat pial mesenteric microvessels; sodium fluorescein; sodium pentobarbital; solute permeability; syringe pump; temperature 37 C; Apertures; Bones; Carotid arteries; Fluorescence; Heating; Lenses; Permeability measurement; Pumps; Rats; Size measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioengineering Conference, 2007. NEBC '07. IEEE 33rd Annual Northeast
Conference_Location
Long Island, NY
Print_ISBN
978-1-4244-1033-0
Electronic_ISBN
978-1-4244-1033-0
Type
conf
DOI
10.1109/NEBC.2007.4413340
Filename
4413340
Link To Document