DocumentCode :
2537152
Title :
Conversion and Comparison of the Test Results in Fully and Semi-Anechoic Chamber
Author :
Yu, ZHOU ; Hongbo, Tao ; Wenjian, Wang ; Shufang, Li
Author_Institution :
Beijing Univ. of Posts & Telecommun., Beijing
fYear :
2007
fDate :
23-26 Oct. 2007
Firstpage :
287
Lastpage :
290
Abstract :
This paper illustrates the test method of the radiated emission in Semi-Anechoic Chamber (SAC), and the radiated power in Fully Anechoic Chamber (FAC) between 30 MHz and 1 GHz. The test results are conversed and compared by analysis, while the correction factors that influence the performance are given.
Keywords :
anechoic chambers (electromagnetic); electromagnetic compatibility; anechoic chamber; electromagnetic test method; frequency 30 MHz to 1 GHz; Antenna measurements; Educational institutions; Electronic equipment testing; Erbium; Monitoring; Open area test sites; Polarization; Power measurement; Receiving antennas; Transmitting antennas; EMC; anechoic chamber; radiated emission; radiated power;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2007. EMC 2007. International Symposium on
Conference_Location :
Qingdao
Print_ISBN :
978-1-4244-1371-3
Electronic_ISBN :
978-1-4244-1372-0
Type :
conf
DOI :
10.1109/ELMAGC.2007.4413487
Filename :
4413487
Link To Document :
بازگشت