• DocumentCode
    2539498
  • Title

    Optimization of anti-corona construction for HV generator and its verification test

  • Author

    Shangchun, Liu ; Xiuhua, Ren ; Jingfu, Li

  • Author_Institution
    Harbin Electr. Machinery Works, China
  • fYear
    1988
  • fDate
    12-16 Sep 1988
  • Firstpage
    662
  • Abstract
    An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method instead of a screening test on a large number of specimens. This approach eliminates local overheating, thermal breakdown, and flashover discharge along or over the surface of the Coronax during a 1-min. Hi-pot test. Also presented are results of a verification test
  • Keywords
    corona; electric generators; high-voltage engineering; machine insulation; machine testing; machine theory; Coronax; HV generator; Runge-Kutta method; anti-corona construction; digital computation; flashover discharge elimination; high voltage; local overheating elimination; optimized anticorona design; physics model; thermal breakdown elimination; verification test; Conductivity; Design optimization; Differential equations; Physics; Power engineering and energy; Power generation; Power systems; System testing; Systems engineering and theory; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1988. Proceedings., Second International Conference on Properties and Applications of
  • Conference_Location
    Beijing
  • Type

    conf

  • DOI
    10.1109/ICPADM.1988.38486
  • Filename
    38486