An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method instead of a screening test on a large number of specimens. This approach eliminates local overheating, thermal breakdown, and flashover discharge along or over the surface of the Coronax during a 1-min. Hi-pot test. Also presented are results of a verification test
Keywords :
corona; electric generators; high-voltage engineering; machine insulation; machine testing; machine theory; Coronax; HV generator; Runge-Kutta method; anti-corona construction; digital computation; flashover discharge elimination; high voltage; local overheating elimination; optimized anticorona design; physics model; thermal breakdown elimination; verification test; Conductivity; Design optimization; Differential equations; Physics; Power engineering and energy; Power generation; Power systems; System testing; Systems engineering and theory; Voltage;