DocumentCode
2539498
Title
Optimization of anti-corona construction for HV generator and its verification test
Author
Shangchun, Liu ; Xiuhua, Ren ; Jingfu, Li
Author_Institution
Harbin Electr. Machinery Works, China
fYear
1988
fDate
12-16 Sep 1988
Firstpage
662
Abstract
An optimized anticorona design (called Coronax) for an HV (high voltage) generator is described which uses digital computation with the Runge-Kutta method instead of a screening test on a large number of specimens. This approach eliminates local overheating, thermal breakdown, and flashover discharge along or over the surface of the Coronax during a 1-min. Hi-pot test. Also presented are results of a verification test
Keywords
corona; electric generators; high-voltage engineering; machine insulation; machine testing; machine theory; Coronax; HV generator; Runge-Kutta method; anti-corona construction; digital computation; flashover discharge elimination; high voltage; local overheating elimination; optimized anticorona design; physics model; thermal breakdown elimination; verification test; Conductivity; Design optimization; Differential equations; Physics; Power engineering and energy; Power generation; Power systems; System testing; Systems engineering and theory; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 1988. Proceedings., Second International Conference on Properties and Applications of
Conference_Location
Beijing
Type
conf
DOI
10.1109/ICPADM.1988.38486
Filename
38486
Link To Document