DocumentCode :
2539749
Title :
Elimination of Dead-time in PWM Controlled Inverters
Author :
Chen, Lihua ; Peng, Fang Z.
Author_Institution :
ECE department, Michigan State University, East Lansing, Michigan 48824 USA
fYear :
2007
fDate :
Feb. 25 2007-March 1 2007
Firstpage :
306
Lastpage :
309
Abstract :
A dead-time elimination method is presented in this paper for PWM controlled inverters. In comparison to using expensive current sensors, this method precisely determines the load current direction by detecting the operating conditions of active devices and their anti-parallel diodes. A low-cost diode-conducting detection circuit is developed to measure the operating status of the anti-parallel diode. In comparison with complicated compensators, this method features with simple logic and flexible implementation. This method significantly reduces the output distortion and regains the RMS value. The principle of proposed dead-time elimination method is described. Simulation and experimental results are given to demonstrate the validity and features of the dead-time elimination method.
Keywords :
Blanking; Circuit simulation; Diodes; Distortion measurement; Leg; Logic devices; Pulse width modulation; Pulse width modulation inverters; Switches; Voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE
Conference_Location :
Anaheim, CA, USA
ISSN :
1048-2334
Print_ISBN :
1-4244-0713-3
Type :
conf
DOI :
10.1109/APEX.2007.357531
Filename :
4195735
Link To Document :
بازگشت