• DocumentCode
    2540450
  • Title

    A Low-Delay Digital PWM Control Circuit for DC/DC onverters

  • Author

    Ishizuka, Yoichi ; Ueno, Masao ; Nishikawa, Ichiro ; Ichinose, Akira ; Matsuo, Hirofumi

  • Author_Institution
    Nagasaki University, 1-14 Bunkyo-machi, Nagasaki-shi, Nagasaki, 852-8521 Japan. isy2@nagasaki-u.ac.jp
  • fYear
    2007
  • fDate
    Feb. 25 2007-March 1 2007
  • Firstpage
    579
  • Lastpage
    584
  • Abstract
    This paper is descried about a proposed scheme of a low-cost digital pulse width modulation (DPWM) control circuit for non-isolated DC-DC converter without A/D converter. Also, real-time PID control technique for DPWM is described. Some experimental results are revealed the proposed circuit and scheme. The purpose of this research is striking a balance between minimizing cost increase by digitalizing of the control circuit of DC-DC converter and speeding up the control circuit.
  • Keywords
    Circuits; Costs; DC-DC power converters; Digital control; Energy management; Field programmable gate arrays; Pulse width modulation; Pulse width modulation converters; Robust control; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE
  • Conference_Location
    Anaheim, CA, USA
  • ISSN
    1048-2334
  • Print_ISBN
    1-4244-0713-3
  • Type

    conf

  • DOI
    10.1109/APEX.2007.357573
  • Filename
    4195777