    Axial type flat PM motor with large air gap

  • Author

    Sanada, Masayuki ; Morimoto, Shigeo ; Takeda, Yoji

  • Author_Institution
    Dept. of Electr. & Electron. Syst., Osaka Prefecture Univ., Japan
  • Volume
    2
  • fYear
    1997
  • fDate
    3-6 Aug 1997
  • Firstpage
    643
  • Abstract
    An axial type flat permanent magnet motor (AFPM motor) is used for audio visual equipment, information actuators, etc. However it is limited to a small capacity with a small air gap. In this paper, the characteristics of the AFPM motor with a large air gap to protect and/or separate between the rotor and the stator for new applications are examined. The tested motor has an 8 mm air gap length and a 170 W output capacity. Maximum efficiency of the tested motor is about 80%, and if the air gap length is spread to 12 mm, the tested motor keeps 66% efficiency. Moreover, it is shown that the steady-state characteristics of the AFPM motor driven by a 6-step inverter can be estimated using d-q coordinates modeling
  • Keywords
    machine testing; machine theory; permanent magnet motors; rotors; stators; 12 mm; 170 W; 66 percent; 8 mm; 80 percent; air gap length; axial-type flat permanent magnet motor; d-q coordinates modeling; large air gap; motor characteristics; output capacity; rotor; six-step inverter; stator; steady-state characteristics; Equations; Magnetic flux; Permanent magnet motors; Permanent magnets; Pulse width modulation inverters; Reluctance motors; Steady-state; Testing; Torque; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Conversion Conference - Nagaoka 1997., Proceedings of the
  • Conference_Location
    Nagaoka
  • Print_ISBN
    0-7803-3823-5
  • Type

    conf

  • DOI
    10.1109/PCCON.1997.638263
  • Filename
    638263