  • Abstract
    A simple, systematic accelerated life test procedure is developed for evaluating the reliability of class F insulation for HV (high-voltage) machines. The tests included electrical aging, thermal aging, and impact strength. Test results for evaluating the reliability of five systems are given
  • Keywords
    ageing; electric generators; high-voltage engineering; impact strength; insulation testing; life testing; machine insulation; machine testing; reliability; HV electric machines; accelerated life test procedure; class F insulation; electrical aging; generators; high-voltage; impact strength; reliability; thermal aging; Corona; Frequency; Insulation; Life estimation; Performance evaluation; Steel; Surface treatment; Temperature; Testing; Vibrations;