Abstract :
Investigations of a glow discharge initiated by an auxiliary glow discharge operating at an elevated pressure in the discharge gap have been performed. The main discharge, due to the pressure difference between the two discharge systems, is initiated with low jitter and operates with a discharge current of up to 400 A and an operating voltage of 300-900 V. Varying the dimensions of the channel connecting the two discharge systems, it is possible to reduce the operating voltage of the main discharge about two times and increase the discharge current by a factor of 1.5-2. It has been demonstrated that with this discharge system emission current densities of up to 100 A/cm2 can be achieved at an extraction voltage of 15 kV
Keywords :
anodes; cathodes; current density; glow discharges; 15 kV; 300 to 900 V; 400 A; auxiliary glow discharge; discharge current; discharge gap; discharge system emission current densities; extraction voltage; hollow-cathode hollow-anode microsecond high-current glow discharge; operating voltage; pressure difference; Anodes; Cathodes; Electrodes; Fault location; Glow discharges; Jitter; Plasma accelerators; Plasma stability; Pulse transformers; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Discharges and Electrical Insulation in Vacuum, 2000. Proceedings. ISDEIV. XIXth International Symposium on
Conference_Location :
Xi´an
Print_ISBN :
0-7803-5791-4
Type :
conf
DOI :
10.1109/DEIV.2000.877321
Filename :
877321
Link To Document :
بازگشت