DocumentCode :
2541010
Title :
An On-Line Stator Turn Fault Detection Method for Interior PM Synchronous Motor Drives
Author :
Lee, Youngkook ; Habetler, Thomas G.
Author_Institution :
School of Electrical and Computer Engineering, Georgia Institute of Technology, 777 Atlantic Drive, Atlanta GA, 30332 USA
fYear :
2007
fDate :
Feb. 25 2007-March 1 2007
Firstpage :
825
Lastpage :
831
Abstract :
An on-line stator turn fault detection scheme, which is suitable for detecting turn faults in interior PM synchronous motor (IPMSM) drives, is proposed in this paper. It is investigatted that the asymmetries in the machine parameters caused by turn faults in current-controlled voltage source inverter (CCVSI)-driven applications result in a reduced positive sequence component of the machine terminal voltages; furthermore, the reduction should be reflected in the voltage references because of the control action on the currents. It is also figured out that the variations in the voltage references can be easily observed in the synchronous rotating reference frame. Based on these facts, a stator turn fault detection method that does not require calculation of sequence components and importantly does not require measurements of the machine terminal voltages is proposed and verified through experiments.
Keywords :
Drives; Electrical fault detection; Fault detection; Impedance; Inverters; Monitoring; Stators; Synchronous motors; Torque; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE
Conference_Location :
Anaheim, CA, USA
ISSN :
1048-2334
Print_ISBN :
1-4244-0713-3
Type :
conf
DOI :
10.1109/APEX.2007.357610
Filename :
4195814
Link To Document :
بازگشت