Abstract
An on-line stator turn fault detection scheme, which is suitable for detecting turn faults in interior PM synchronous motor (IPMSM) drives, is proposed in this paper. It is investigatted that the asymmetries in the machine parameters caused by turn faults in current-controlled voltage source inverter (CCVSI)-driven applications result in a reduced positive sequence component of the machine terminal voltages; furthermore, the reduction should be reflected in the voltage references because of the control action on the currents. It is also figured out that the variations in the voltage references can be easily observed in the synchronous rotating reference frame. Based on these facts, a stator turn fault detection method that does not require calculation of sequence components and importantly does not require measurements of the machine terminal voltages is proposed and verified through experiments.
Keywords
Drives; Electrical fault detection; Fault detection; Impedance; Inverters; Monitoring; Stators; Synchronous motors; Torque; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Applied Power Electronics Conference, APEC 2007 - Twenty Second Annual IEEE
Conference_Location
Anaheim, CA, USA
ISSN
1048-2334
Print_ISBN
1-4244-0713-3
Type
conf
DOI
10.1109/APEX.2007.357610
Filename
4195814
Link To Document