DocumentCode
2541401
Title
Fault Tolerant Control for EMS systems with sensor failure
Author
Michail, Konstantinos ; Zolotas, Argyrios ; Goodall, Roger ; Pearson, John
Author_Institution
Dept. of Electron. & Electr. Eng., Loughborough Univ., Loughborough, UK
fYear
2009
fDate
24-26 June 2009
Firstpage
712
Lastpage
717
Abstract
The paper presents a method to recover the performance of an EMS (Electromagnetic suspension) under faulty air gap measurement. The controller is a combination of classical control loops, a Kalman estimator and analytical redundancy (for the air gap signal). In case of a faulty air gap sensor the air gap signal is recovered using the Kalman filter and analytical redundancy. Simulations verify the proposed sensor Fault Tolerant Control (FTC) method for the EMS system.
Keywords
Kalman filters; electromagnetic devices; fault tolerance; magnetic levitation; Kalman estimator; Kalman filter; air gap signal; analytical redundancy; control loop; electromagnetic suspension; fault tolerant control; faulty air gap measurement; faulty air gap sensor; sensor failure; Automatic control; Control systems; Electromagnets; Fault tolerance; Fault tolerant systems; Magnetic levitation; Medical services; Rails; Redundancy; Sensor systems;
fLanguage
English
Publisher
ieee
Conference_Titel
Control and Automation, 2009. MED '09. 17th Mediterranean Conference on
Conference_Location
Thessaloniki
Print_ISBN
978-1-4244-4684-1
Electronic_ISBN
978-1-4244-4685-8
Type
conf
DOI
10.1109/MED.2009.5164627
Filename
5164627
Link To Document