DocumentCode
2542127
Title
Techniques for calibration of the scale factor and image center for high accuracy 3D machine vision metrology
Author
Lenz, Reimar K. ; Tsai, Roger Y.
Author_Institution
IBM T. J. Watson Research Center Yorktown Heights, NY.
Volume
4
fYear
1987
fDate
31837
Firstpage
68
Lastpage
75
Abstract
This paper describes techniques for calibrating certain intrinsic camera parameters for machine vision. The parameters to be calibrated are the horizontal scale factor, i.e. the factor that relates the sensor element spacing of a discrete array camera to the picture element spacing after sampling by the image acquisition circuitry, and the image center, i.e. the intersection of the optical axis with the camera sensor. The scale factor calibration uses a 1D-FFT and is accurate and efficient. It also permits the use of only one coplanar set of calibration points for general camera calibration. Three groups of techniques for center calibration are presented: Group I requires using a laser and a four-degree of freedom adjustment of its orientation, but is simplest in concept, and is accurate and reproducible. Group II is simple to perform, but is less accurate than the other two. The most general Group III is accurate and efficient, but requires accurate image feature extraction of calibration points with known 3D coordinates. A feasible setup is described. Results of real experiments are presented and compared with theoretical predictions. Accuracy and reproducibility of the calibrated parameters are reported, as well as the improvement in actual 3D measurement due to center calibration.
Keywords
Calibration; Cameras; Circuits; Image sampling; Image sensors; Machine vision; Metrology; Optical arrays; Optical sensors; Sensor arrays;
fLanguage
English
Publisher
ieee
Conference_Titel
Robotics and Automation. Proceedings. 1987 IEEE International Conference on
Type
conf
DOI
10.1109/ROBOT.1987.1088012
Filename
1088012
Link To Document