Identification of system wide disturbances using synchronized phasor data and ellipsoid method
Author
Lingling Fan ; Kavasseri, Rajesh ; Zhixin Miao ; Osborn, Dale ; Bilke, Terry
Author_Institution
North Dakota State Univ., Fargo, ND
fYear
2008
fDate
20-24 July 2008
Firstpage
1
Lastpage
10
Abstract
With phasor measurement units (PMU) installed in power systems, synchronized measurements are now available in real time. These global measurements can be utilized to develop real time visualization and system monitoring tools. The characteristic ellipsoid (or minimum volume enclosing ellipsoid (MVEE)) method is one such recently proposed tool for identification of system disturbances.This paper examines: (i) the effectiveness of different input signals and (ii) the attributes (volume, orientation and position) of the ellipsoid that are most sensitive in detecting a system wide disturbance. Specifically, we consider two Eastern interconnection events namely: (a) a frequency deviation event arising from a substantial loss of generation and (b) an angle deviation transient. Real time system wide PMU data corresponding to (i) bus frequencies (ii) voltage magnitudes and (iii) phase angles are considered as inputs to the MVEE algorithm and the sensitivities of the ellipsoid attributes are studied for these inputs for the two disturbances. From the study, the most appropriate (input signal, attribute) pair is identified to detect a given system disturbance. This preliminary study can be potentially useful in designing a dashboard to enhance real-time wide area situational awareness of the power grid.
Keywords
computerised monitoring; power grids; power system faults; Eastern interconnection; MVEE algorithm; minimum volume enclosing ellipsoid method; phasor measurement units; power grid; power systems; real time visualization; synchronized phasor data; system disturbance identification; system monitoring; Data visualization; Ellipsoids; Frequency synchronization; Monitoring; Phasor measurement units; Position sensitive particle detectors; Power measurement; Power system measurements; Real time systems; Signal processing; Angle Transient; Ellipsoid method; Frequency Deviation; PMU;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008 IEEE
Conference_Location
Pittsburgh, PA
ISSN
1932-5517
Print_ISBN
978-1-4244-1905-0
Electronic_ISBN
1932-5517
Type
conf
DOI
10.1109/PES.2008.4596721
Filename
4596721
Link To Document