DocumentCode
2543985
Title
Further investigations with GEM detectors for use on the ISIS spallation neutron source
Author
Duxbury, D.M. ; Rhodes, N.J. ; Schooneveld, E.M. ; Spill, E.J.
Author_Institution
Technol. Dept., Rutherford Appleton Lab., Didcot, UK
fYear
2012
fDate
Oct. 27 2012-Nov. 3 2012
Firstpage
131
Lastpage
133
Abstract
The Gaseous Electron Multiplier (GEM) technology promises to deliver 3He based neutron detectors for a wide range of applications for the spallation neutron source ISIS. These devices offer a high rate capability and when used in conjunction CF4 as a quench gas they offer the potential of a sub mm resolution 2D detector for thermal neutron detection. The operation of these devices at elevated CF4 pressures (necessary for reducing the proton range) however has proved to be somewhat challenging. A program of work was undertaken at RAL to determine whether these devices are appropriate for deployment on the ISIS instruments.
Keywords
helium-3 counters; ionisation chambers; neutron detection; neutron sources; nuclear spallation; 3He based neutron detectors; GEM detectors; ISIS instruments; ISIS spallation neutron source; gaseous electron multiplier; quench gas; submm resolution 2D detector; thermal neutron detection;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location
Anaheim, CA
ISSN
1082-3654
Print_ISBN
978-1-4673-2028-3
Type
conf
DOI
10.1109/NSSMIC.2012.6551076
Filename
6551076
Link To Document