• DocumentCode
    2543985
  • Title

    Further investigations with GEM detectors for use on the ISIS spallation neutron source

  • Author

    Duxbury, D.M. ; Rhodes, N.J. ; Schooneveld, E.M. ; Spill, E.J.

  • Author_Institution
    Technol. Dept., Rutherford Appleton Lab., Didcot, UK
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    131
  • Lastpage
    133
  • Abstract
    The Gaseous Electron Multiplier (GEM) technology promises to deliver 3He based neutron detectors for a wide range of applications for the spallation neutron source ISIS. These devices offer a high rate capability and when used in conjunction CF4 as a quench gas they offer the potential of a sub mm resolution 2D detector for thermal neutron detection. The operation of these devices at elevated CF4 pressures (necessary for reducing the proton range) however has proved to be somewhat challenging. A program of work was undertaken at RAL to determine whether these devices are appropriate for deployment on the ISIS instruments.
  • Keywords
    helium-3 counters; ionisation chambers; neutron detection; neutron sources; nuclear spallation; 3He based neutron detectors; GEM detectors; ISIS instruments; ISIS spallation neutron source; gaseous electron multiplier; quench gas; submm resolution 2D detector; thermal neutron detection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551076
  • Filename
    6551076