Abstract :
Boron-Lined neutron detector may be a substitute of 3He proportional counter in the field of thermal neutron detection. We present in this paper the simulation results of the detection efficiency and energy response of the boron-lined detector. Thickness of natural or enriched B4C, which is used as the neutron converter to emit charged particles to form signals in proportional gas, is researched to achieve the optimized efficiency for a single detector or the whole detector array. The relationships between the rate of spurious events caused by scattering and row number or thickness of the substrate of the detectors are also researched.
Keywords :
neutron detection; proportional counters; B4C; boron-lined neutron detector; boron-lined straw-tube detector array; charged particle emission; neutron converter; neutron scattering measurement; proportional gas; single detector array; thermal neutron detection; whole detector array;