Title :
Aspects of the safety analysis performed for the IGNITOR machine
Author :
Carpignano, A. ; Franzoni, G. ; Porfiri, M.T.
Author_Institution :
Dipartimento di Energetica, Politecnico di Torino, Italy
fDate :
30 Sep-5 Oct 1995
Abstract :
The paper discusses some aspects of the safety analysis currently being performed for a compact high-field tokamak device (IGNITOR). The analysis has shown that the radioactive releases from the last containment barrier that could occur during major accidents are negligible when comparing IGNITOR with similar fusion devices. The paper focuses on some of the design solutions, suggested by the analysis, in order to improve the overall plant availability
Keywords :
Tokamak devices; fusion reactor safety; IGNITOR machine; compact high-field tokamak device; last containment barrier; overall plant availability; radioactive releases; safety analysis; Accidents; Availability; Failure analysis; Fault diagnosis; Ignition; Information analysis; Magnetic analysis; Performance analysis; Safety devices; Tokamak devices;
Conference_Titel :
Fusion Engineering, 1995. SOFE '95. Seeking a New Energy Era., 16th IEEE/NPSS Symposium
Conference_Location :
Champaign, IL
Print_ISBN :
0-7803-2969-4
DOI :
10.1109/FUSION.1995.534421