  • Abstract
    The pseudo transient-analysis method is regarded as one of the most effective method to find DC operating points for nonlinear circuits. In this paper, we combine the ramping method and the damped pseudo-transient analysis algorithm together in order to improve the simulation efficiency. By combing the two algorithms together, the oscillation problem and time-consuming problems can be greatly eliminated. Numerical examples are shown to demonstrate the efficiency of proposed algorithms.
  • Keywords
    damping; nonlinear network analysis; numerical analysis; oscillations; transient analysis; DC operating point; damped PTA algorithm; nonlinear circuit; numerical algorithm; oscillation problem; pseudotransient-analysis method; ramping method; time-consuming problem; Algorithm design and analysis; Convergence; Inductors; Integrated circuit modeling; Oscillators; SPICE; Transient analysis; DC analysis; DC operating points; nonlinear circuits; pseudo-transient analysis;