Title :
Standalone trailing probe for aerometrical measurements
Author :
Paces, Pavel ; Popelka, Jan ; Auersvald, J.
Author_Institution :
Czech Tech. Univ. in Prague, Prague, Czech Republic
Abstract :
The paper presents the sensor evaluated by DRUCK GE6000 automated pressure controller for wind tunnel tests. The total port almost independent on AOA (and AOS). The probe head dP/Pc ratio reaches 1.6. There is negligible deviation between the probe measurement system and laboratory measurement instruments. The total absolute error after calibration is +/6 Pa.
Keywords :
aircraft instrumentation; altimeters; velocity measurement; wind tunnels; DRUCK GE6000 automated pressure controller; aerometrical measurements; air speed indicator; altimeter; standalone trailing probe; wind tunnel test;
Conference_Titel :
Digital Avionics Systems Conference (DASC), 2012 IEEE/AIAA 31st
Conference_Location :
Williamsburg, VA
Print_ISBN :
978-1-4673-1699-6
DOI :
10.1109/DASC.2012.6382946