• DocumentCode
    2548855
  • Title

    Ion back flow reduction in a THGEM based detector

  • Author

    Alexeev, M. ; Azevedo, C.D.R. ; Birsa, R. ; Bradamante, F. ; Bressan, A. ; Chiosso, M. ; Ciliberti, P. ; Correia, P.M.M. ; Dalla Torre, S. ; Dasgupta, S.S. ; Denisov, O. ; Duic, V. ; Finger, M. ; Finger, M. ; Fischer, H. ; Giorgi, M. ; Gobbo, B. ; Gregori

  • Author_Institution
    Sez. di Trieste, INFN, Trieste, Italy
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    1165
  • Lastpage
    1171
  • Abstract
    Cherenkov imaging counters requiring large photosensitive areas, the capability to stand high rates and to operate in magnetic field environments could benefit from the use of micropattern gas detectors based on THick Gaseous Electron Multiplier (THGEM) coupled to a solid state CsI photo-cathode. Nevertheless, the ions produced in the charge multiplication processes, which end up in the CsI photocathode Ion Back Flow (IBF) compromise the detector performance: fast ageing of the CsI photocathode, as well as electron extraction resulting in spurious signals and eventual discharges can occur. To avoid and limit these undesired events, several configurations of THGEM based detectors were considered. Some changing the whole detector geometry by changing the relative position of individual THGEMs to take advantage of the microscopic diffusion properties of electrons and ions. One other configuration changing directly the geometry of the THGEM itself to better create an ion trap, the THCOBRA, is also studied. In this work, experimental and simulation studies of these configurations is performed, particularly concerning IBF and gain. Finite element method calculations and Monte-Carlo simulations are performed for a better understanding of the results.
  • Keywords
    Cherenkov counters; Monte Carlo methods; finite element analysis; gas scintillation detectors; geometry; ionisation chambers; photocathodes; solid-state nuclear track detectors; Cherenkov imaging counters; CsI; Monte-Carlo simulation; THCOBRA; THGEM based detector; charge multiplication processes; detector geometry; electron extraction; fast ageing; finite element method; ion back flow reduction; magnetic field environments; micropattern gas detectors; microscopic diffusion properties; photocathode ion back flow; photosensitive areas; solid state CsI photocathode; thick gaseous electron multiplier; Ion Back Flow; Micropattern Gas Detectors; RICH; THCOBRA; THGEM;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551292
  • Filename
    6551292