DocumentCode :
2550736
Title :
Gamma sensitivity of a ZnS:Ag(6-LiF) wavelength shifting fiber neutron detector in mixed neutron-gamma fields
Author :
Sykora, Garrett Jeff ; Schooneveld, E.M. ; Rhodes, N.J. ; Van Eijck, Lambert
Author_Institution :
ISIS Dept., Rutherford Appleton Labs., Didcot, UK
fYear :
2012
fDate :
Oct. 27 2012-Nov. 3 2012
Firstpage :
1567
Lastpage :
1571
Abstract :
Gamma sensitivity of an ISIS linear position sensitive wavelength shifting fiber (WLSF) detector was evaluated at the Reactor Institute Delft (RID) using 60Co and 137CS sources. The caveat of quoting gamma sensitivity of a detector in pure gamma fields is that detectors are never operated in gamma only environments. A concern is that the sensitivity may increase during neutron measurements due to the increase of pulse pile-up which can occur in ZnS:Ag detectors as the afterglow of a neutron event coincides with a gamma scintillation event causing the gamma event to appear brighter than it actually was. For this reason, gamma sensitivity measurements were performed on a time of flight neutron reflectometer at RID. Results presented here detail neutron efficiency and rate capability of the detector as well as demonstrate gamma sensitivity in pure gamma and mixed fields. It is shown that, in a pure gamma field, the detector has gamma sensitivity on the order of 10-7-10-6 for 60Co and 10-9-10-8 for 137Cs as a result of detector geometry, fibre coding and signal processing. Gamma sensitivity is unchanged to any statistical significance in a mixed neutron gamma field. A less than 1% gamma-induced deadtiming at neutron rates above 5kHz and high gamma flux on the order of 104 gammas/second/cm2 was observed.
Keywords :
gamma-ray detection; neutron detection; radioactive sources; reflectometers; solid scintillation detectors; 60Co source; I37Cs source; ISIS linear position sensitive wavelength shifting fiber detector; Reactor Institute Delft; ZnS:Ag wavelength shifting fiber neutron detector; detector geometry; fibre coding; gamma scintillation event; gamma sensitivity measurements; gamma-induced dead-timing; mixed neutron-gamma fields; neutron efficiency; signal processing; time-of-flight neutron reflectometer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
Conference_Location :
Anaheim, CA
ISSN :
1082-3654
Print_ISBN :
978-1-4673-2028-3
Type :
conf
DOI :
10.1109/NSSMIC.2012.6551374
Filename :
6551374
Link To Document :
بازگشت