DocumentCode
2550743
Title
Retrofit of a recovery boiler ID fan with a dual channel high reliability LCI drive
Author
Poole, James N. ; Frey, William J.
Author_Institution
CRS Sirrine Inc., Research Triangle Park, NC, USA
fYear
1988
fDate
6-10 June 1988
Firstpage
23
Lastpage
37
Abstract
A dual-channel load-commutating inverter (LCI) drive and synchronous motor was applied, as a retrofit, to drive an existing induced-draft fan on a 1200 ton recovery boiler at Union Camp Corporation´s paper mill located in Franklin, Virginia. The fan was originally driven by a steam turbine. For reliability, two channels of fully rated power-conversion equipment were provided. Parallel operation is the normal mode, with automatic transfer to the unfaulted channel when a fault occurs in the channel selected as the primary channel. The application and drive technology is described and discussed in detail. The economics approach and results that justified the retrofit are also described.<>
Keywords
electric drives; invertors; maintenance engineering; paper industry; synchronous motors; Union Camp Corporation; dual channel drive; induced-draft fan; load commutating inverter drive; paper mill; power-conversion equipment; recovery boiler; retrofit; synchronous motor; Bleaching; Boilers; Commutation; Inverters; Milling machines; Paper mills; Power generation economics; Synchronous motors; Turbines; Variable speed drives;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulp and Paper Industry Technical Conference, 1988., Conference Record of 1988 Annual
Conference_Location
Milwaukee, WI, USA
Type
conf
DOI
10.1109/PAPCON.1988.10897
Filename
10897
Link To Document