• DocumentCode
    2550743
  • Title

    Retrofit of a recovery boiler ID fan with a dual channel high reliability LCI drive

  • Author

    Poole, James N. ; Frey, William J.

  • Author_Institution
    CRS Sirrine Inc., Research Triangle Park, NC, USA
  • fYear
    1988
  • fDate
    6-10 June 1988
  • Firstpage
    23
  • Lastpage
    37
  • Abstract
    A dual-channel load-commutating inverter (LCI) drive and synchronous motor was applied, as a retrofit, to drive an existing induced-draft fan on a 1200 ton recovery boiler at Union Camp Corporation´s paper mill located in Franklin, Virginia. The fan was originally driven by a steam turbine. For reliability, two channels of fully rated power-conversion equipment were provided. Parallel operation is the normal mode, with automatic transfer to the unfaulted channel when a fault occurs in the channel selected as the primary channel. The application and drive technology is described and discussed in detail. The economics approach and results that justified the retrofit are also described.<>
  • Keywords
    electric drives; invertors; maintenance engineering; paper industry; synchronous motors; Union Camp Corporation; dual channel drive; induced-draft fan; load commutating inverter drive; paper mill; power-conversion equipment; recovery boiler; retrofit; synchronous motor; Bleaching; Boilers; Commutation; Inverters; Milling machines; Paper mills; Power generation economics; Synchronous motors; Turbines; Variable speed drives;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulp and Paper Industry Technical Conference, 1988., Conference Record of 1988 Annual
  • Conference_Location
    Milwaukee, WI, USA
  • Type

    conf

  • DOI
    10.1109/PAPCON.1988.10897
  • Filename
    10897